Warning:  The EBRAINS Lab will be down today from 21:00 CEST (my timezone)  for ~10 minutes for an update


Last modified by puchades on 2022/02/18 13:55

From version 21.3
edited by puchades
on 2020/04/07 16:15
Change comment: There is no comment for this version
To version 18.2
edited by puchades
on 2020/04/07 16:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,12 +11,14 @@
11 11  
12 12  == (% style="color:#c0392b" %)Preparation of the image series(%%) ==
13 13  
14 -Before you get started with image registration, make sure your images are the right size, and files are named according to the QUINT naming convention. See [[2. Image pre-processing with Nutil Transform>>doc:Collabs.quint.1\. Preparing the images.WebHome]] for details.
14 +Resize your raw 2D images to 24-bit PNG and JPEG. Images can be loaded up to the resolution of 16 megapixels (e.g.4000x4000 or 5000x3000 pixels), however QuickNII does not benefit from image resolutions exceeding the resolution of the monitor in use.
15 15  
16 -=== (% style="color:#c0392b" %)Generate your image descriptor file with FileBuilder(%%) ===
16 +(% style="color:#4e5f70" %)The resized files must follow the naming convention having an unique ID in the format: sXXX.., with XXX.. reflecting the serial order and spacing of the sections (e.g. s002, s006, s010 for every 4^^th^^ section starting with section 2).
17 17  
18 -(% style="color:#4e5f70" %)Use the small program “FileBuilder.bat” provided with //QuickNII//. A new window will open, and ask for the folder where your images are located. Point to the correct folder, mark all image files, and click OK. **An XML file is generated**. **Always save this file in the same folder as the resized images.**
18 +=== (% style="color:#c0392b" %)Generate your images descriptor file with FileBuider(%%) ===
19 19  
20 +(% style="color:#4e5f70" %)Use the small program “FileBuilder.bat” provided with //QuickNII//. A new window will open, and ask for the folder where your images are located. Point to the correct folder, mark all image files, and click ok. **An XML file is generated**. **Always save this file in the same folder as the resized images.**
21 +
20 20  == (% style="color:#c0392b" %)Open //QuickNII// and load your images(%%) ==
21 21  
22 22  (% style="color:#4e5f70" %)Open the //QuickNII// program from the .exe file. Once the program opens, click the **Manage data button** and load your XML file.
... ... @@ -23,30 +23,22 @@
23 23  
24 24  A detailed //QuickNII// user manual as well as a demo dataset can be found on [[https:~~/~~/www.nitrc.org/projects/quicknii/>>https://www.nitrc.org/projects/quicknii/]]
25 25  
28 +>(% style="color:#27ae60" %)The idea is to determine the cutting angles (dorso-ventral and medio-lateral) for the whole series as these should be consistent throughout. Once found in a few sections, apply the same angles to the rest of the series.
29 +
26 26  == (% style="color:#c0392b" %)**Anchoring procedure**(%%) ==
27 27  
28 -(% class="box infomessage" %)
29 -(((
30 -The alignment procedure consists of two main tasks:
32 +**The basic steps are:**
31 31  
32 -1. Determine the dorsoventral and mediolateral cutting angle of the section series, apply same angles for all slices.
33 -1. Adjust the atlas slices generated along these angles to match individual sections.
34 -)))
34 +(% style="color:#000000" %)-(%%)Open one image in the beginning of the series and use anatomical landmarks to find the approximate anteroposterior position of the section. Select the atlas modality to be overlayed on the image (MRI, Atlas, etc..)
35 35  
36 -=== (% style="color:#c0392b" %)A) To determine the cutting angles:(%%) ===
36 +-Use the** transparency slider** continuously to determine how well the atlas fits the section. Determine the sectioning angles (dorso-ventral and medio-lateral) by tilting the atlas and adjust the atlas borders.
37 37  
38 -1. Open an image in the beginning of the series, and use anatomical landmarks to find the approximate anteroposterior position of the section in the atlas. Select the atlas modality to be overlaid on the image (MRI, Atlas, etc.)
39 -1. Tilt the atlas by adjusting the dorsoventral and mediolateral angles. Move the transparency slider back and forth to see how well the atlas fits the section. The size of the atlas slice can also be modified for a better fit.
40 -1. Once you have a fairly good match, save the alignment settings for this section and move on with the anchoring procedure. The settings can be fine-tuned later.
41 -1. Open another image, located at the other end of the series, and repeat the same procedure as above:, i.e. find the approximate anteroposterior position of the section, and test how well the cutting angles fit this section. Save your settings.
42 -1. Explore a few sections throughout the series in order to and find the angles that fit most sections in order to achieve a good global anchoring. Ideally, the cutting angles should be consistent throughout the entire section series.
43 -1. Once two or more sections are anchored at their approximate position within the brain, QuickNII propagates the cutting angles across the entire image series. The anteroposterior position of the images is also estimated based on the section numbering.
38 +-Save the positions for this section for now, they can be adjust later.
44 44  
45 -=== (% style="color:#c0392b" %)B) To fine-tune your alignment:(%%) ===
40 +-Open another image, located at the other end of the series, and repeat the same procedure as above, i.e. find the approximate anteroposterior position of the section and test how well the cutting angles fit this section. Save the positions.
46 46  
47 -Review the position of **all sections** in the series, adjust the width and height of atlas slices as necessary, **and save settings**.
42 +-Explore a few sections in order to find the angles that fit most sections in order to achieve a global anchoring.
48 48  
49 -
50 50  -By having the same cutting angles set for two sections (i.e. ML=+1; DV= -4), //QuickNII// will apply them to all the sections located between them. The antero-posterior positions of all the images are also estimated based on the numbering.
51 51  
52 52  -Review the atlas to section match for all the sections, adjusting the atlas borders as necessary, and save.